6-28
WorkCentre 7132
IOT NVM List
Reversion 4.0
General procedures information
Chain 746-xxx Chain 747-xxx Xfer
744-199 Fine Adjustment of Fuser Mot Speed: heavy 2 20376 19540~22344 RW 79mm/s (-0.2%)
744-200 Fuser Mot Off Time 200 0~255 10msec RW Detects Exit SNR OFF.
744-201 Fuser Mot Off Time half speed 82 0~255 10msec RW Detects Exit SNR OFF.
744-266 Fine Adjustment of Fuser Mot Speed
coated paper 1 B/W
10235 9770~11172 RW 158mm/s(-0.7%)
744-267 Fine Adjustment of Fuser Mot Speed
coated paper 1 F/C
20440 19540~22344 RW 79mm/s(-0.5%)
Table 4 Fuser
Chain-Link Name Default Range Step
Read/
Write Description
Table 5 Xfer
Chain-Link Name Default Range Description
746-001 Environment control execution switch 1 0~1 Environment control execution switch
746-002 Compulsory designated environment NO 5 0~9 Compulsory designated environment NO
746-003 The relative temperature threshold value to specify environment NO. #0 22 0~100 The relative temperature threshold value to specify environment NO. #0
746-004 absolute humidity AH threshold value to specify environment NO. #0 3 0~20 absolute humidity AH threshold value to specify environment NO. #0
746-005 Storage of calculated value of absolute humidity 10 0~255 Stores a calculated value of absolute humidity.
746-006 Storage of selected Environment No. 5 0~9 Stores a selected Environment No.
746-007 1st BTR On Timing 60 0~200 1st BTR On Timing
746-008 1st BTR Output changeover Timing (Y->M->C) 45 0~200 1st BTR Output changeover Timing (Y->M->C)
746-009 1st BTR Output changeover Timing (full->half) 0 0~50 1st BTR Output changeover Timing (full->half)
746-010 1st BTR Off Timing (full) 56 0~200 1st BTR Off Timing (full Speed)
746-011 1st BTR Off Timing (half) 464 300~550 1st BTR Off Timing (halfSpeed)
746-012 The amount of a film compensation electric current 2 0~20 The amount of a film compensation electric current
746-013 A film decreases, compensation electric current calculation result storage 0 0~255 A film decreases, compensation electric current calculation result storage
746-014 1st BTR Mode environment revise (BW_Side1) 100 0~200 1st BTR Mode environment revise (BW_Side1)
746-015 1st BTR Mode environment revise (BW_Side2) 100 0~200 1st BTR Mode environment revise (BW_Side2)
746-016 1st BTR Mode environment revise (FC_Side1) 100 0~200 1st BTR Mode environment revise (FC_Side1)
746-017 1st BTR Mode environment revise (FC_Side2) 100 0~200 1st BTR Mode environment revise (FC_Side2)
746-018 1st BTR Halfspeed time output compensation coefficient 50 0~200 1st BTR Halfspeed time output compensation coefficient
746-020 1st BTR Environment compensation coefficient NotUsually
(environment NO.1-3_K)
100 0~200 1st BTR Environment compensation coefficient NotUsually
(environment NO.1-3_K)
746-021 1st BTR Environment compensation coefficient NotUsually
(environment NO.4-6_K)
100 0~200 1st BTR Environment compensation coefficient NotUsually
(environment NO.4-6_K)
746-022 1st BTR Environment compensation coefficient NotUsually
(environment NO.7_K)
100 0~200 1st BTR Environment compensation coefficient NotUsually
(environment NO.7_K)
746-023 1st BTR Environment compensation coefficient NotUsually
(environment NO.8-9_K)
100 0~200 1st BTR Environment compensation coefficient NotUsually
(environment NO.8-9_K)
746-024 1st BTR Environment compensation coefficient NotUsually
(environment NO.0_YMC)
100 0~200 1st BTR Environment compensation coefficient NotUsually
(environment NO.0_YMC)