January 2007
6-27
WorkCentre 7132
IOT NVM List
General procedures information
Reversion 4.0
744-111 B/W Plain Paper SEF Setup Temperature 5 0~5 RW Control Table No.
0: 1-1
1: 1-2
2: 1-3
3: 2-1
4: 2-2
5: 2-3
744-112 B/W Heavy 1 SEF Setup Temperature 1 0~2 RW Control Table No.
0: 3-1 heavy 1 (setup temp-low)
1: 3-2 heavy 1 (standard)
2: 3-3 heavy 1 (setup temp-high)
744-113 B/W Heavy 2 SEF Setup Temperature 2 0~2 RW Control Table No.
0: 4-1
1: 4-2
2: 4-3
744-114 F/C Plain Paper SEF Setup Temperature 5 0~5 RW Control Table No.
0: 6-1
1: 6-2
2: 6-3
3: 7-1
4: 7-2
5: 7-3
744-115 F/C Heavy 1 SEF Setup Temperature 1 0~2 RW Control Table No.
0: 8-1 heavy 1 (setup temp-low)
1: 8-2 heavy 1 (standard)
2: 8-3 heavy 1 (setup temp-high)
744-116 F/C Heavy 2 SEF Setup Temperature 2 0~2 RW Control Table No. 0:9-1, 1:9-2, 2:9-3
744-125 Environment Temp Correction Coefficient 5 0~5 RW Max. correction temp based on Environment Sensor-detected temp
0: No correction
1: 2 degrees C
2: 4 degrees C
3: 6 degrees C
4: 8 degrees C
5: 10 degrees C
744-127 Environment Correction Operating Temp 35 20~50 1 deg C RW Reads Environment Sensor temp if NCS-Center temp equals or is lower
than NVM value.
744-139 Temp Shift Time at Power On 15 0~30 1min RW Time taken to increase 5 degrees C at Power On
744-140 Individual Action mode for Plain Paper BW Mode
Poor Fusing
0 0~1 RW 0: Individual action OFF
1: Individual action ON
744-141 Individual Action mode for Poor Fusing: Shift Temp 2 0~10 RW Shift temp in relation to Run temp
744-181 Condensation Prevention Mode 0 0~15 1min RW how long to wait since the attainment of Ready Temp in Condensation Pre-
vention mode
744-196 Fine Adjustment of Fuser Mot Speed: plain paper 10292 9770~11172 RW 158mm/s (-1.2%)
744-197 Fine Adjustment of Fuser Mot Speed: heavy 1 B/W 10292 9770~11172 RW 158mm/s (-1.2%)
744-198 Fine Adjustment of Fuser Mot Speed: heavy 1 F/C 20480 19540~22344 RW 79mm/s (-0.7%)
Table 4 Fuser
Chain-Link Name Default Range Step
Read/
Write Description