EasyManua.ls Logo

Xerox WorkCentre 7132 - Page 1350

Xerox WorkCentre 7132
1726 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
January 2007
6-27
WorkCentre 7132
IOT NVM List
General procedures information
Reversion 4.0
744-111 B/W Plain Paper SEF Setup Temperature 5 0~5 RW Control Table No.
0: 1-1
1: 1-2
2: 1-3
3: 2-1
4: 2-2
5: 2-3
744-112 B/W Heavy 1 SEF Setup Temperature 1 0~2 RW Control Table No.
0: 3-1 heavy 1 (setup temp-low)
1: 3-2 heavy 1 (standard)
2: 3-3 heavy 1 (setup temp-high)
744-113 B/W Heavy 2 SEF Setup Temperature 2 0~2 RW Control Table No.
0: 4-1
1: 4-2
2: 4-3
744-114 F/C Plain Paper SEF Setup Temperature 5 0~5 RW Control Table No.
0: 6-1
1: 6-2
2: 6-3
3: 7-1
4: 7-2
5: 7-3
744-115 F/C Heavy 1 SEF Setup Temperature 1 0~2 RW Control Table No.
0: 8-1 heavy 1 (setup temp-low)
1: 8-2 heavy 1 (standard)
2: 8-3 heavy 1 (setup temp-high)
744-116 F/C Heavy 2 SEF Setup Temperature 2 0~2 RW Control Table No. 0:9-1, 1:9-2, 2:9-3
744-125 Environment Temp Correction Coefficient 5 0~5 RW Max. correction temp based on Environment Sensor-detected temp
0: No correction
1: 2 degrees C
2: 4 degrees C
3: 6 degrees C
4: 8 degrees C
5: 10 degrees C
744-127 Environment Correction Operating Temp 35 20~50 1 deg C RW Reads Environment Sensor temp if NCS-Center temp equals or is lower
than NVM value.
744-139 Temp Shift Time at Power On 15 0~30 1min RW Time taken to increase 5 degrees C at Power On
744-140 Individual Action mode for Plain Paper BW Mode
Poor Fusing
0 0~1 RW 0: Individual action OFF
1: Individual action ON
744-141 Individual Action mode for Poor Fusing: Shift Temp 2 0~10 RW Shift temp in relation to Run temp
744-181 Condensation Prevention Mode 0 0~15 1min RW how long to wait since the attainment of Ready Temp in Condensation Pre-
vention mode
744-196 Fine Adjustment of Fuser Mot Speed: plain paper 10292 9770~11172 RW 158mm/s (-1.2%)
744-197 Fine Adjustment of Fuser Mot Speed: heavy 1 B/W 10292 9770~11172 RW 158mm/s (-1.2%)
744-198 Fine Adjustment of Fuser Mot Speed: heavy 1 F/C 20480 19540~22344 RW 79mm/s (-0.7%)
Table 4 Fuser