January 2007
6-72
WorkCentre 7132
IOT NVM List
Reversion 4.0
General procedures information
Chain 764-xxx Finisher
762-048 Down Step Timing 3 50 0~500 RW In Step Down in Step Control, Vm 2 hours
762-049 Up Step Timing 1 207 0~1000 RW the timing of starting Step Up in Step Control (layout difference from BCR: 227ms-
20ms)
762-050 Up Step Timing 2 50 0~500 RW In Step Up in Step Control, Vm 2 hours
762-051 Up Step Timing 3 50 0~500 RW In Step Up in Step Control, Vm 3 hours
762-052 ESCAPE_INT_TIME_HALF_K 8830 0~10000 RW BW Rest Time (8330ms) in Kesc after speed reduction
762-053 ESCAPE DEVE DC HALF 100 1~1000 RW Cin (in speed reduction) for generating band for color that passes the develop-
ment position
762-054 INT_ROT_TIME_FC 693 0~2000 RW the timing of starting rotating Rotary in FC after speed reduction (693ms before
image)
762-055 Deve_Bias_DC_Nominal 570 1~1000 RW Deve Bias DC Value when Voltage Control Off
762-056 ROT_BAND_WARNING 0 0~1 RW Whether to rotate Rotary with P/R not in operation
762-057 ROT_TIME_LIMIT 2000 0~5000 RW Fail Time Threshold (ms) in Home Positioning
762-058 ROT_TIME_SHORT_YMC 2947 2000~4000 RW the timing of rotating Rotary during Print YMC (1)
762-059 ROT_TIME_SHORT_K 3057 2000~4000 RW the timing of rotating Rotary during Print K (1)
762-060 ROT_TIME_MID_YMC 1207 0~2000 RW the timing of rotating Rotary during Print YMC (2)
762-061 ROT_TIME_MID_K 1318 0~2000 RW the timing of rotating Rotary during Print K (2)
762-062 ROT_TIME_LONG_YMCK 1 0~500 RW the timing of rotating Rotary during Print YMCK
762-063 CHANGE_INT_RECOVERY 200 0~2000 RW Wait Time (200ms) in changing color during the recovery operation
762-064 Cartridge First Set UP 0 0~1 RW Installing Operation at installation
0: Yes
1: No
762-244 DEVE_UNIT_LIFE 420000 0~840000 RW Developer Unit Life
762-245 DEVE_UNIT_LIFE_WARNING 418500 0~840000 RW Warning on Developer Unit
Table 12 Deve
Chain-Link Name Default Range Read/Write Description
Table 13 Output Control
Chain-Link Name Default Range Description
764-002 B-Fin Sleep Mode Recovery Indicate 0 0~1 Indicates whether Finisher has recovered from Sleep Mode.
1: Recovery from Sleep Mode
0: Power ON in any case other than the above
764-003 Fin Decurler On Level 0 -50~50 Curl Amount based on which Finisher Decurler should be turned on
764-004 Fin Sheet Width of Last EjectedSheet 0 0~65535 the width (in steps of 0.1mm) of the top sheet of a stack of paper on Finisher Stacker
(Rewrite in Sleep Mode)
764-005 Fin Sheet Length of Last EjectedSheet 0 0~65535 the length (in steps of 0.1mm) of the top sheet of a stack of paper on Finisher Stacker
(Rewrite in Sleep Mode)
764-006 Fin Sheet Width of Maximum SizeSheet 0 0~65535 the width (in steps of 0.1mm) of the largest sheet of a stack of paper on Finisher Stacker)
(Rewrite in Sleep Mode)
764-007 Fin Sheet Length of Maximum SizeSheet 0 0~65535 the length (in steps of 0.1mm) of the largest sheet of a stack of paper on Finisher Stacker)
(Rewrite in Sleep Mode)