January 2007
6-129
WorkCentre 7132
Controller & Fax NVM List
General procedures information
Reversion 4.0
790-350 Fixed Size 12 of Scan Docu-
ment Size Input
1~255 88: Postcard
SEF
Read/
Write
1: Not fixed, 10: A3 SEF, 11: A4 LEF, 12: A4 SEF, 13: A5 LEF, 14: A5 SEF, 15: A6 LEF, 16: A6 SEF, 50:
Envelope: C4 SEF, 51: Envelope: C5 LEF, 55: Envelope: DL LEF, 66: B4 SEF, 67: B5 LEF, 68: B5 SEF,
69: B6 LEF, 70: B6 SEF, 80: 11x17 SEF, 87: Postcard LEF, 88: Postcard SEF, 89: 8.5x11 LEF, 90:
8.5x11 SEF, 92: 8.5x14 SEF, 94: 12x18 SEF, 98: 12x19 SEF, 101: 16K LEF, 102: 16K SEF, 104: 8K
SEF, 105: PostCard (3.5x5.5) LEF, 106: PostCard (3.5x5.5) SEF, 107: PostCard (4x6) LEF, 108: Post
-
Card (4x6) SEF, 109: PostCard (5x7) LEF, 110: PostCard (5x7) SEF, 111: 5.5x8.5 LEF, 112: 5.5x8.5
SEF, 113: PostCard (6x9) LEF, 114: PostCard (6x9) SEF, 115: 8x10 LEF, 116: 8x10 SEF, 118: 8.5x13
SEF, 119: 7.25x10.5 LEF, 120: 7.25x10.5 SEF, 123: Envelope: You Chou 3 LEF, 124: Envelope:
Choukei 3SEF, 126: Envelope: Choukei 4SEF, 132: 11x15 SEF, 135: 3.5x5 (Photo L) LEF, 136: 3.5x5
(Photo L) SEF, 137: Envelope: Commercial#10 LEF, 139: 215x315mm (8.46x12.4) SEF, 141: SRA3
SEF, 142: Special A3 SEF, 143: Special A4 LEF, 144: Special A4 SEF, 145: A4Cover SEF, 146:
A4Cover LEF, 147: 13x19 SEF, 148: 13x18 SEF, 149: 12.6x19.2 SEF, 150: Letter Cover (9x11) SEF,
151: LetterCover (9x11) LEF, 152: Envelope: Monarch7.3/4 LEF, 154: Return Postcard LEF, 155: Return
Postcard SEF, 156: 16K LEF (mainland China), 157: 16K SEF (mainland China), 159: 8K SEF (main
-
land China)
790-351 Fixed Size 13 of Scan Docu-
ment Size Input
1~255 80: 11x17 SEF Read/
Write
ditto
790-352 Fixed Size 14 of Scan Docu-
ment Size Input
1~255 92: 8.5x14
SEF
Read/
Write
ditto
790-353 Fixed Size 15 of Scan Docu-
ment Size Input
1~255 118: 8.5x13
SEF
Read/
Write
ditto
790-354 Fixed Size 16 of Scan Docu-
ment Size Input
1~255 90: 8.5x11
SEF
Read/
Write
ditto
790-355 Fixed Size 17 of Scan Docu-
ment Size Input
1~255 89: 8.5x11 LEF Read/
Write
ditto
790-360 Fixed Size 12 Fast Scan 0~297 NULL Read/
Write
15~297mm *Default Value is “0”
790-361 Fixed Size 12 Slow Scan 0~432 NULL Read/
Write
15~432mm *Default Value is “0”
790-362 Fixed Size 13 Fast Scan 0~297 NULL Read/
Write
15~297mm *Default Value is “0”
790-363 Fixed Size 13 Slow Scan 0~432 NULL Read/
Write
15~432mm *Default Value is “0”
790-364 Fixed Size 14 Fast Scan 0~297 NULL Read/
Write
15~297mm *Default Value is “0”
790-365 Fixed Size 14 Slow Scan 0~432 NULL Read/
Write
15~432mm *Default Value is “0”
790-366 Fixed Size 15 Fast Scan 0~297 NULL Read/
Write
15~297mm *Default Value is “0”
790-367 Fixed Size 15 Slow Scan 0~432 NULL Read/
Write
15~432mm *Default Value is “0”
790-368 Fixed Size 16 Fast Scan 0~297 NULL Read/
Write
15~297mm *Default Value is “0”
790-369 Fixed Size 16 Slow Scan 0~432 NULL Read/
Write
15~432mm *Default Value is “0”
Table 8 UI
Chain-Link NVM Name
Setup
Range Initial Value
Read/
Write Description