January 2007
6-154
WorkCentre 7132
Controller & Fax NVM List
Reversion 4.0
General procedures information
825-079 Call Restriction for Ch2 0~1 0: Outgoing/Incom-
ing Call
Read/Write 0: Outgoing/Incoming Call, 1: Outgoing Call only
825-080 Call Restriction for Ch3 0~1 0: Outgoing/Incom-
ing Call
Read/Write 0: Outgoing/Incoming Call, 1: Outgoing Call only
825-081 Call Restriction for Ch4 0~1 0: Outgoing/Incom-
ing Call
Read/Write 0: Outgoing/Incoming Call, 1: Outgoing Call only
825-082 Call Restriction for Ch5 0~1 0: Outgoing/Incom-
ing Call
Read/Write 0: Outgoing/Incoming Call, 1: Outgoing Call only
825-103 RX Gain in G3 Communication Mode 0~15 6 (-6dB) Read/Write 0~-15dB
825-104 TX Gain in ISDN G3 Communication Mode 0~15 0 Read/Write 0~-15dB
825-115 PB Pause Time. PB (DTMF) Dial Inter-digit
Pause Time.
0~255 102 Read/Write 0~255 (ms)
825-127 Attenuates analog transmission to attenu-
ated Transmission Analog Output by
modem for Channel 0.
8~15 8: 8dBm Read/Write 8: 8dBm~15: 15dBm, step: -1dBm
825-128 Attenuates analog transmission to attenu-
ated Transmission Analog Output by
modem for Channel 1.
8~15 8: 8dBm Read/Write 8: 8dBm~15: 15dBm, step: -1dBm
825-129 Attenuates analog transmission to attenu-
ated Transmission Analog Output by
modem for Channel 2.
8~15 8: 8dBm Read/Write 8: 8dBm~15: 15dBm, step: -1dBm
825-130 Attenuates analog transmission to attenu-
ated Transmission Analog Output by
modem for Channel 3.
8~15 15: 15dBm Read/Write 8: 8dBm~15: 15dBm, step: -1dBm
825-131 Attenuates analog transmission to attenu-
ated Transmission Analog Output by
modem for Channel 4.
8~15 8: 8dBm Read/Write 8: 8dBm~15: 15dBm, step: -1dBm
825-132 Attenuates analog transmission to attenu-
ated Transmission Analog Output by
modem for Channel 5.
8~15 15: 15dBm Read/Write 8: 8dBm~15: 15dBm, step: -1dBm
825-133 Busy Tone detection (On/Off) setting 0~1 1: Detect Busy Tone Read/Write 0: Do not detect Busy Tone, 1: Detect Busy Tone
825-134 Dial Tone detection (On/Off) setting 0~1 0: Do not detect dial
tone
Read/Write 0: Do not detect dial tone, 1: Detect dial tone
825-158 No. of sheets transmitted in the transmis-
sion result report (Cannot be changed
because of ROM data)
0~1 0 Read/Write 0: Total No. of sheets for resending in the same transmission 1:
Total No. of sheets for each connection
825-159 ECM Capability (Auto Error Resending fea-
ture): A feature that starts resending auto-
matically when an error that occurred
during transmission has been repaired.
0~1 1: Enable Read/Write 0: Disable, 1: Enable
825-160 Time before the CNG Signal starts to be
sent. Time that has elapsed after dialing
has completed and when the initial CNG
signal starts to be sent
20~140 60: 3000ms Read/Write 20: 1 second~140: 7 seconds, 1: 50msec
Table 11 NVM 825 FAX Service
Chain-Link NVM Name
Setup
Range Initial Value Read/Write Description