RX23W Group 50. Flash Memory (FLASH)
50.7.3 Software Commands
Software commands consist of commands for programming and erasure and commands for programming start-up
program area information and access window information.
Table 50.5 lists the software commands for use with the flash
memory.
Table 50.5 Software Commands
Command Function
Program ROM programming (8 bytes)
E2 DataFlash programming (1 byte)
Block erase ROM/E2 DataFlash erasure
All-block erase Erasure of all blocks in the ROM/E2 DataFlash
Blank check Check whether the specified area is blank.
Confirm that data is not programmed in the area. This command does not guarantee
whether the area remains erased.
Start-up area information program Rewrite the start-up area switching information used for start-up program protection.
Access window information program Set the access window used for area protection.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Renesas RX Series and is the answer not in the manual?

Renesas RX Series Specifications

General IconGeneral
CoreRXv1, RXv2, RXv3
Flash MemoryUp to 8 MB
RAMUp to 1 MB
Operating Voltage1.62V to 5.5V
Operating Temperature-40°C to +85°C or +105°C
PackageBGA, LQFP
ADC Resolution12-bit
DAC Resolution12-bit
Communication InterfacesSCI, SPI, I2C, USB, Ethernet, CAN
Architecture32-bit
Security FeaturesMemory Protection Unit (MPU)

Related product manuals