RX23W Group 10. Clock Frequency Accuracy Measurement Circuit (CAC)
10.5 Usage Notes
10.5.1 Module Stop Function Setting
CAC operation can be disabled or enabled using module stop control register C (MSTPCRC). The initial setting is for the
CAC to be halted. Register access is enabled by releasing the module stop state. For details, refer to
section 11, Low
Power Consumption
.