RX23W Group 50. Flash Memory (FLASH)
Figure 50.13 Procedure to Issue the Program Command for the E2 DataFlash
Start in E2 DataFlash
P/E mode
Set programming address in registers
FSARH and FSARL
Yes
Set programming data
in registers FWB0
FCR register = 81h
FCR register = 00h
FSTATR1.FRDY flag = 1?
End in E2 DataFlash
P/E mode
No
FSTATR1.FRDY flag = 0?
Yes
No
Yes
No
Yes
No
FSTATR0.ILGLERR flag = 1 or
FSTATR0.PRGERR flag = 1?
FRESETR.FRESET bit = 1
FRESETR.FRESET bit = 0
Sequencer
initialization
Continue E2 DataFlash
programming?
Yes
No
Program continuous area?
FASR.EXS bit = 0