R01UH0823EJ0100 Rev.1.00 Page 472 of 1823
Jul 31, 2019
RX23W Group 23. Multi-Function Timer Pulse Unit 2 (MTU2a)
Table 23.2 MTU Functions (1/2)
Item MTU0 MTU1 MTU2 MTU3 MTU4
Count clocks PCLK/1
PCLK/4
PCLK/16
PCLK/64
MTCLKA
MTCLKB
MTCLKC
MTCLKD
PCLK/1
PCLK/4
PCLK/16
PCLK/64
PCLK/256
MTCLKA
MTCLKB
PCLK/1
PCLK/4
PCLK/16
PCLK/64
PCLK/1024
MTCLKA
MTCLKB
MTCLKC
PCLK/1
PCLK/4
PCLK/16
PCLK/64
PCLK/256
PCLK/1024
MTCLKA
MTCLKB
PCLK/1
PCLK/4
PCLK/16
PCLK/64
PCLK/256
PCLK/1024
MTCLKA
MTCLKB
External clocks for phase
counting mode
—MTCLKA
MTCLKB
MTCLKC
MTCLKD
——
General registers (TGR) TGRA
TGRB
TGRE
TGRA
TGRB
TGRA
TGRB
TGRA
TGRB
TGRA
TGRB
General registers/
buffer registers
TGRC
TGRD
TGRF
——TGRC
TGRD
TGRC
TGRD
I/O pins MTIOC0A
MTIOC0B
MTIOC0C
MTIOC1A
MTIOC1B
MTIOC2A
MTIOC2B
MTIOC3A
MTIOC3B
MTIOC3C
MTIOC3D
MTIOC4A
MTIOC4B
MTIOC4C
MTIOC4D
Counter clear function TGR compare
match or input
capture
TGR compare
match or input
capture
TGR compare
match or input
capture
TGR compare
match or input
capture
TGR compare
match or input
capture
Compare
match
output
Low output

High output 
Toggle output 
Input capture function 
Synchronous operation 
PWM mode 1 
PWM mode 2 ——
Complementary PWM mode

Reset-synchronized PWM 
AC synchronous motor drive
mode
—— 
Phase counting mode ——
Buffer operation
—— 
Dead time compensation
counter function
—————
DMAC activation TGRA compare
match or input
capture
TGRA compare
match or input
capture
TGRA compare
match or input
capture
TGRA compare
match or input
capture
TGRA compare
match or input
capture
DTC activation TGR compare
match or input
capture
TGR compare
match or input
capture
TGR compare
match or input
capture
TGR compare
match or input
capture
TGR compare
match or input
capture and TCNT
overflow or
underflow
A/D converter start trigger TGRA compare
match or input
capture
TGRB compare
match or input
capture
TGRE compare
match
TGRF compare
match
TGRA compare
match or input
capture
TGRA compare
match or input
capture
TGRA compare
match or input
capture
TGRA compare
match or input
capture
TCNT underflow
(trough) in
complementary
PWM mode