6-24
WorkCentre 7132
IOT NVM List
Reversion 4.0
General procedures information
742-245 Timing of Temporarily Stopping Duplex Transporting
Operation
(color/L<=216mm)
87 0~174 1.5ms RW Timing of turning Off Duplex Motor to stop paper at the Wait Station
(Duplex Wait Sensor ON to Duplex Motor OFF)
742-246 Timing of Starting Duplex Feed Operation
(Exit1/color/L<=216mm)
67 0~134 1.5ms RW Timing of turning On Duplex Motor to restart feeding paper
742-247 Duplex Regi Loop Adjustment Timing (plain paper) 43 0~110 1.5ms RW Loop Amount Adjustment (Dup/plain paper)
Time from Regi Snr On to Dup Motor Off
742-248 Duplex Regi Loop Adjustment Timing (heavy 1) 43 0~110 1.5ms RW Loop Amount Adjustment (Dup/heavy 1)
Time from Regi Snr On to Dup Motor Off
742-249 Timing of Starting Duplex Post-Regi Pushing (plain paper) 0 0~134 1.5ms RW Adjusts the timing of activating Duplex Motor for Regi projection.
(Dup/plain paper/common)
742-250 Timing of Starting Duplex Post-Regi Pushing (heavy 1) 0 0~134 1.5ms RW Adjusts the timing of activating Duplex Motor for Regi projection
(Dup/heavy 1, coated 1/B)
742-251 Timing of Starting Duplex Post-Regi Pushing (L<=216) 20 0~40 10.5ms RW Adjusts the timing of stopping Duplex Motor after Regi projection (small size)
742-252 Timing of Starting Duplex Post-Regi Pushing (L>216) 20 0~40 10.5ms RW Adjusts the timing of stopping Duplex Motor after Regi projection (large size)
742-261 OCT Operation Limit 0 0~1 RW BAM
0: Operation permitted
1: Operation prohibited
742-262 Timing of Starting OCT Initializing Operation 30 0~60 10ms RW Adjusts the timing of starting to initialize OCT.
(From Regi Start to #2Offset Motor Homing On)
742-263 Timing of Starting Offset Operation (full speed/L<=216) 23 0~30 10ms RW Adjusts the timing of starting Offset Operation. (full speed/L<=216)
(From Exit2 Snr Off to Offset Motor On)
742-264 Timing of Starting Offset Operation (full speed/L>216) 0 0~30 10ms RW Adjusts the timing of starting Offset Operation. (full speed/L>216)
(From Exit Snr2 Off to Offset Motor On)
742-265 Timing of Starting Offset Operation (half speed/L<=216) 30 0~40 20ms RW Adjusts the timing of starting Offset Operation. (half speed/L<=216)
(From Exit2 Snr Off to Offset Motor On)
742-266 Timing of Starting Offset Operation (half speed/L>216) 0 0~30 20ms RW Adjusts the timing of starting Offset Operation. (half speed/L>216)
(From Exit Snr2 Off to Offset Motor On)
742-267 Timing of Starting Return Operation (full speed/L<=216) 15 0~60 10ms RW Adjusts the timing of starting Return-to-Offset Operation. (full speed/L<=216)
(From Exit2 Snr Off to Offset Motor On)
742-268 Timing of Starting Return Operation (full speed/L>216) 15 0~60 10ms RW Adjusts the timing of starting Return-to-Offset Operation. (full speed/L>216)
(From Exit Snr2 Off to Offset Motor On)
742-269 Timing of Starting Return Operation (half speed/L<=216) 17 0~60 20ms RW Adjusts the timing of starting Return-to-Offset Operation. (half speed/L<=216)
(From Exit2 Snr Off to Offset Motor On)
742-270 Timing of Starting Return Operation (half speed/L>216) 17 0~60 20ms RW Adjusts the timing of starting Return-to-Offset Operation. (half speed/L>216)
(From Exit Snr2 Off to Offset Motor On)
742-271 Limit on Countermeasure against Condensation 0 0~1 RW Sets whether or not to rotate #2 Exit Drive Motor in outputting paper from #1Exit
in Simplex mode.
0: enabled
1: disabled
742-272 Timing of Starting Countermeasure Operation against
Condensation
1 1~250 1ñá RW Timing of starting to rotate #2 Exit Drive Motor; Adjusts the number of a series
of sheets for which the countermeasure against condensation is intended, in
order to start the control.
Table 3 Paper Handling
Chain-Link Name Default Range
Step
(mm)
Read/
Write Description