094-201 IBT CLN Retract Sensor - BTR CLN Retract Sensor on/off is detected.
[I/O]
094-202 TRO Sensor - Same as Name
094-203 POB Sensor - Same as Name
Table 2 Output Component Control Codes IOT
Chain-Link Name
Connector
Level
Meaning Timer Off Cycle Operation Remarks
010-001 Fuser Motor (Normal Speed) H Fuser motor rotation at 158mm/sec.
[I/O] Fuser Motor On
[I/O] Fuser Gain1
X X
010-002 Fuser Motor (Half Speed) L Fuser motor rotation at 79mm/sec.
[I/O] Fuser Motor On
[I/O] Fuser Gain1
X X
012-020 Front Tamper Motor Low FRONT ON/OFF - Same as Name X X
012-021 Front Tamper Motor Middle FRONT ON/
OFF
- Same as Name X X
012-022 Front Tamper Motor High FRONT ON/
OFF
- Same as Name X X
012-023 Front Tamper Motor Low REAR ON/OFF - Same as Name X X
012-024 Front Tamper Motor Middle REAR ON/
OFF
- Same as Name X X
012-025 Front Tamper Motor High REAR ON/OFF - Same as Name X X
012-026 Rear Tamper Motor Low FRONT ON/OFF - Same as Name X X
012-027 Rear Tamper Motor Middle FRONT ON/
OFF
- Same as Name X X
012-028 Rear Tamper Motor High FRONT ON/OFF - Same as Name X X
012-029 Rear Tamper Motor Low REAR ON/OFF - Same as Name X X
012-030 Rear Tamper Motor Middle REAR ON/
OFF
- Same as Name X X
012-031 Rear Tamper Motor High REAR ON/OFF - Same as Name X X
012-040 Stapler Move Motor Low FRONT ON/OFF - Same as Name X X
012-042 Stapler Move Motor High FRONT ON/OFF - Same as Name X X
012-043 Stapler Move Motor Low REAR ON/OFF - Same as Name X X
012-045 Stapler Move Motor High REAR ON/OFF - Same as Name X X
012-046 Staple Motor FORWARD ON/OFF H Same as Name X X
012-047 Staple Motor REVERSE ON/OFF H Same as Name X X
012-051 Set Clamp Paddle - Same as Name X X
012-060 Stacker Motor UP ON/OFF H Same as Name X X
012-061 Stacker Motor DOWN ON/OFF H Same as Name X X
012-080 Main Drive Motor ON/OFF L Same as Name X X
Table 1 Input Component Control Codes IOT
Chain-Link Name
Connector
Level Meaning Remarks