3 Short-Range Comms & IoT Mode
3.11 IQ Waveform Measurement
-2.402406506109E+001
Case #2 - Trace IQ: returns a double array of two values, the first is I, and the second is Q
>:CALC:WAV:MARK1:Y?
-3.006944493834E-003,+9.9870666467354E-004
The IQ selection is for backwards compatibility purposes. For new designs, use the I and/or Q selection
instead
You must be in a Mode that includes the Waveform measurement to use this command. Use :INSTru-
ment:SELect to set the Mode
Preset Result depends on the marker setup and signal source
State Saved No
Backwards
Compatibility
SCPI
:CALCulate:WAVeform:MARKer[1]|2|…|12:FUNCtion:RESult?
Marker Mode
Sets the marker control mode to POSition, DELTa, or OFF. All interactions and
dependencies detailed under the control description are enforced when the remote
command is sent. If the selected marker is OFF, pressing Marker sets it to POSition
(Normal) and places it at the center of the screen on the trace determined by the
Marker Trace rules. At the same time, Marker X-Axis Value appears on the Active
Function area.
The default active function is the active function for the currently selected marker
control mode. If the current control mode is OFF, there is no active function, and the
active function is turned off.
Remote
Command
:CALCulate:WAVeform:MARKer[1]|2|…|12:MODE POSition | DELTa | OFF
:CALCulate:WAVeform:MARKer[1]|2|…|12:MODE?
Example
:CALC:WAV:MARK:MODE OFF
:CALC:WAV:MARK:MODE?
Preset
OFF
State Saved Saved in instrument state
Range
POSition|DELTa|OFF
Annotation Mkr # <X value> and <Marker value> upper right on graph
When Marker Trace is Polar in WCDMA mode:
Mkr # <Chip Value (RHO & QPSKEVM)/Symbol Value (CDP)>, <X value> and <Y value> upper right on
graph
Short Range Comms & IoT Mode User's &Programmer's Reference 1583