3 Short-Range Comms & IoT Mode
3.7 ACP Measurement
Example
:CONF:ACP
Couplings Selecting Meas Preset restores all measurement parameters to their default values
3.7.13.2 Reference
All ACP measurements are taken relative to a specific carrier frequency, relative to
whose power the offset channel power is measured.
The controls on this tab let you specify the reference carrier frequency and other
parameters relevant to the reference carrier.
Number of Carriers
Specifies the number of carriers to be measured.
Remote Command
[:SENSe]:ACPower:CARRier[1]|2:COUNt <integer>
[:SENSe]:ACPower:CARRier[1]|2:COUNt?
Subopcode: 1 = BTS/Downlink (Default), 2 = MS/Uplink
Example
:ACP:CARR:COUN 1
:ACP:CARR:COUN?
Notes Note that Carrier subopcode 2 is not supported in some Modes. In those cases, Carrier subopcode 1 is
used for both BTS and MS and commands with subopcode 2 are accepted without error but ignored
Dependencies When Number of Carriers is 1, Ref Carrier is grayed out
Does not appear in MSR, LTEAFDD, LTEATDD and 5G NR Modes. In order to maintain backwards
compatibility with legacy LTE FDD/TDD Modes, the SCPI command is supported in the LTE-A
converged applications
Couplings Changing this parameter might affect "Span" on page 849
Preset 1
State Saved Saved in instrument state
Min/Max 1/18
Backwards
Compatibility SCPI
[:SENSe]:MCPower:CARRier[1]|2:COUNt
(Power Suite)
Carrier/Offset/Limits Config
This is the same dialog as "Carrier/Offset/Limits Config" on page 865 in the Settings
menu.
906 Short Range Comms & IoT Mode User's &Programmer's Reference