7 Save/Recall/Print
7.2 Recall
Dependencies Not supported by all measurements. The tab does not appear at all if no measurements in the Mode
support it
Errors are reported if the file is empty or missing, or if the file type does not match, or if there is a
mismatch between the file type and the destination data type
Couplings When a complex correction file is loaded from mass storage, it is automatically turned ON and Apply
Corrections is set ON. This allows you to see its effect, thus confirming the load
Annotation After recall is complete, an advisory is displayed in the message bar confirming which file was recalled
7.2.19 Select Complex Correction
Selects the register into which the recalled Complex Correction will be placed, for
example, Complex Correction 1.
Preset Not part of Preset, but is reset to Correction 1 by Restore Input/Output Defaults
Survives a shutdown
7.2.20 Recall VDI CCD Correction
Imports VDI CCD External Mixer Correction files in the PC-readable CSV (.csv)
format.
The default path for VDI CCD External Mixer Correction files is the instrument’s My
Documents folder.
Remote Command
:MMEMory:LOAD:VCORrection <filename>
Example
:MMEM:LOAD:VCOR "vdi_ccd_corr.csv"
Dependencies Requires the EXW (External Mixing Wide Bandwidth) and Ampcor (Amplitude Correction) licenses
VDI CCD Corrections are not supported by all measurements. The tab does not appear at all if no
measurements in the Mode support it
Errors are reported if the file is empty or missing, or if the file type does not match, or if there is a
mismatch between the file type and the destination data type
If the file is empty, message –250 is reported. If the file does not exist, message –256 is reported. If
there is a mismatch between the file and the destination data type, message –250 is reported
Couplings When a VDI CCD correction file is loaded into memory, if the correction matches the current external
mixer setup and "Select VDI CCD Correction" on page 2064 is NONE, the selected VDI CCD Correction
is set to the serial number of the matching correction data
Annotation After recall is complete, an advisory is displayed in the message bar confirming which file was recalled
Short Range Comms & IoT Mode User's &Programmer's Reference 2237

Table of Contents

Other manuals for Keysight x-series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight x-series and is the answer not in the manual?

Keysight x-series Specifications

General IconGeneral
Analysis BandwidthUp to 1 GHz (depending on model)
Real-Time BandwidthUp to 1 GHz (depending on model)
Form FactorBenchtop
ConnectivityLAN, USB, GPIB
Resolution Bandwidth1 Hz to 10 MHz (depending on model)

Related product manuals