3 Short-Range Comms & IoT Mode
3.7 ACP Measurement
Modes Values
SA -45, -60, 0, 0, 0, 0 | -45, -60, 0, 0, 0, 0
WCDMA -44.2, -49.2, -49.2, -49.2, -49.2, -49.2 | -32.2, -42.2, -42.2, -42.2, -
42.2, -42.2
LTEAFDD, LTEATDD,
MSR
-44.2,-44.2,-44.2,-44.2,-44.2,-44.2 | -29.2, -29.2, -29.2, -29.2, -29.2,
-29.2
5G NR -43.8, -43.8, -43.8, -43.8, -43.8, -43.8 | -29.2, -29.2, -29.2, -29.2, -
29.2, -29.2
Radio Test -60, -60, -60, 0, 0, 0
State Saved Saved in instrument state
Min/Max -150.0/50.0
Backwards
Compatibility
SCPI
:CALCulate:MCPower:OFFSet:LIST:LIMit:POSitive[:UPPer]:DATA
(Power Suite)
Negative Offset Limit(Remote Command only)
Enables you to set the upper limit for the lower segment of the specified offset pair.
Remote
Command
:CALCulate:ACPower:OFFSet[1]|2[:OUTer]:LIST:LIMit:NEGative[:UPPer]:DATA
<real>,...
:CALCulate:ACPower:OFFSet[1]|2[:OUTer]:LIST:LIMit:NEGative[:UPPer]:DATA?
Subopcode: 1 = BTS/Downlink (Default), 2 = MS/Uplink
Example
:CALC:ACP:OFFS:LIST:LIM:NEG:DATA 0,0,0,0,0,0
:CALC:ACP:OFFS:LIST:LIM:NEG:DATA?
Notes Some Modes do not support Offset subopcode 2. In those cases, commands with subopcode 2 are
accepted without error but ignored
Preset When "Max Num of Offsets" on page 902 is 12, the preset value of Offset G ~ L is the same as the Offset
F value
Modes Values
SA -45, -60, 0, 0, 0, 0 | -45, -60, 0, 0, 0, 0
WCDMA -44.2, -49.2, -49.2, -49.2, -49.2, -49.2 | -32.2, -42.2, -42.2, -42.2, -
42.2, -42.2
LTEAFDD, LTEATDD,
MSR
-44.2, -44.2, -44.2, -44.2, -44.2, -44.2 | -29.2, -29.2, -29.2, -29.2, -
29.2, -29.2
5G NR -43.8, -43.8, -43.8, -43.8, -43.8, -43.8 | -29.2, -29.2, -29.2, -29.2, -
29.2, -29.2
Radio Test -60, -60, -60, 0, 0, 0
Short Range Comms & IoT Mode User's &Programmer's Reference 885

Table of Contents

Other manuals for Keysight x-series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight x-series and is the answer not in the manual?

Keysight x-series Specifications

General IconGeneral
Analysis BandwidthUp to 1 GHz (depending on model)
Real-Time BandwidthUp to 1 GHz (depending on model)
Form FactorBenchtop
ConnectivityLAN, USB, GPIB
Resolution Bandwidth1 Hz to 10 MHz (depending on model)

Related product manuals