3 Short-Range Comms & IoT Mode
3.7 ACP Measurement
Preset
OFF
State Saved Saved in instrument state
Range
OFF|ON
Backwards
Compatibility
SCPI
:CALCulate:ACPower:MARKer[1]|2|…|12:STATe OFF | ON | 0 | 1
:CALCulate:ACPower:MARKer[1]|2|…|12:STATe?
Delta Marker (Reset Delta)
Pressing this button has exactly the same effect as pressing DELTa in Marker Mode.
The selected marker becomes a Delta marker. If the selected marker is already a
Delta marker, the reference marker is moved to the current position of the selected
marker, thus resetting the delta to zero.
Marker Settings Diagram
Lets you configure the Marker system using a visual utility.
All Markers Off
Turns off all markers.
Remote Command
:CALCulate:ACPower:MARKer:AOFF
Example
:CALC:ACP:MARK:AOFF
Dependencies Unavailable when "Meas Method" on page 863 is RBW
Couple Markers
When this function is ON, moving any marker causes an equal X-Axis movement of
every other marker that is not OFF. By “equal X-Axis movement” we mean that we
preserve the difference between each marker’s X-Axis value (in the fundamental X-
Axis units of the trace that marker is on), and the X-Axis value of the marker being
moved (in the same fundamental X-Axis units).
This may result in markers going off screen.
Remote Command
:CALCulate:ACPower:MARKer:COUPle[:STATe] ON | OFF | 1 | 0
:CALCulate:ACPower:MARKer:COUPle[:STATe]?
Example
:CALC:ACP:MARK:COUP ON
:CALC:ACP:MARK:COUP?
Dependencies Unavailable when "Meas Method" on page 863 is RBW
856 Short Range Comms & IoT Mode User's &Programmer's Reference

Table of Contents

Other manuals for Keysight x-series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight x-series and is the answer not in the manual?

Keysight x-series Specifications

General IconGeneral
Analysis BandwidthUp to 1 GHz (depending on model)
Real-Time BandwidthUp to 1 GHz (depending on model)
Form FactorBenchtop
ConnectivityLAN, USB, GPIB
Resolution Bandwidth1 Hz to 10 MHz (depending on model)

Related product manuals