3 Short-Range Comms & IoT Mode
3.2 Modulation Analysis Measurement
Remote
Command
:CALCulate:EVM:LIMit:FERRor:PPM <real>
:CALCulate:EVM:LIMit:FERRor:PPM?
Example
:CALC:EVM:LIM:FERR:PPM 40.0
:CALC:EVM:LIM:FERR:PPM?
Preset 40.0
State Saved Yes
Min/Max 0.0 / 5.0e5
Clock Error
This control enables you to set the limit for the symbol clock error measurement
pass/fail test.
Remote
Command
:CALCulate:EVM:LIMit:CERRor:PPM <real>
:CALCulate:EVM:LIMit:CERRor:PPM?
Example
:CALC:EVM:LIM:CERR:PPM 80.0
:CALC:EVM:LIM:CERR:PPM?
Preset 40.0
State Saved Yes
Min/Max 0.0 / 5.0e5
Deviation Accuracy
Available only when the demodulation format is 2-FSK.
This control enables you to set the limit for the Deviation Accuracy result pass/fail
test.
Remote
Command
:CALCulate:EVM:LIMit:DEViation:OFFSet <real>
:CALCulate:EVM:LIMit:DEViation:OFFSet?
Example
:CALC:EVM:LIM:DEV:OFFS 10.0
:CALC:EVM:LIM:DEV:OFFS?
Couplings Available only when the radio standard is Z-Wave and demodulation format is 2-FSK
If FSK Deviation Reference is Auto, this control will be grey out. And pressing this control in this case, a
message “It’s not available while FSK Reference Deviation is Auto.” is generated
Preset 20.0
State Saved Yes
Min/Max 0.00/100.0
Short Range Comms & IoT Mode User's &Programmer's Reference 297