3 Short-Range Comms & IoT Mode
3.6 Power Stat CCDF Measurement
Standard Compatibility
ZigBee (IEEE 802.15.4)
Z-Wave (ITU-T G.9959)
LoRa
TM
CSS HRP UWB
Channel Power Yes Yes No
ACP Yes No No
SEM Yes No Yes
OBW Yes Yes No
Spurious Emissions Yes Yes No
CCDF Yes Yes No
IQ Waveform Yes Yes No
Monitor Spectrum Yes Yes No
Modulation Analysis (Digital) Yes No No
LoRa CSS Demod (Analog) No Yes No
Preset to Std
This group of controls lets you easily set up the analyzer for ZigBee (IEEE 802.15.4),
Z-Wave (ITU-T G.9959) , LoRa
TM
CSS or HRP UWB measurements.
Remote Command
[:SENSe]:RADio:STANdard:PRESet ZIGBEE2450 | ZIGBEE915 | ZIGBEE868 |
ZBOQPSK780 | ZBOQPSK915 | ZBOQPSK868 | ZWAVER1 | ZWAVER2 | ZWAVER3 | LORA7K
| LORA10K | LORA15K | LORA20K | LORA31K | LORA41K | LORA62K | LORA125K |
LORA203K | LORA250K | LORA406K | LORA500K | LORA812K | LORA1625K | HUWB500M
Example
:RAD:STAN:PRES ZIGBEE2450
Activates the preset for ZigBee 2450
Notes “Preset to Standard” was re-designed using cascading list dialog in XA25, thus all radio standards and
the associated preset options are accessible at one time (prior to XA25, users need to select Radio
Standard first, then select “preset to standard” which were conditionally shown according to the
selected radio standard.)
The selected Radio Standard and Preset results are displayed on the top of Meas Standard menu
panel
Dependencies “Preset to Std” will set “Radio Standard” accordingly, though it was changed to a SCPI only setting for
backward compatibility
Range 802.15.4 OQPSK 2450 MHz | 802.15.4 BPSK 915 MHz | 802.15.4 BPSK 868/950 MHz | 802.15.4
OQPSK 780 MHz | 802.15.4 OQPSK 915 MHz | 802.15.4 OQPSK 868 MHz | Z-Wave R1 (9.6 kbps) FSK |
Z-Wave R2 (40 kbps) FSK | Z-Wave R3 (100kbps) GFSK | LoRa CSS 7.815 kHz| LoRa CSS 10.4167 kHz|
LoRa CSS 15.625 kHz| LoRa CSS 20.8333 kHz| LoRa CSS 31.25 kHz| LoRa CSS 41.667 kHz| LoRa CSS
62.5 kHz| LoRa CSS 125 kHz| LoRa CSS 203.125 kHz| LoRa CSS 250 kHz| LoRa CSS 406.25 kHz| LoRa
CSS 500 kHz| LoRa CSS 812.5 kHz| LoRa CSS 1625 kHz | HRP UWB 499.2 MHz
Before XA25, there were three power measurements included in this mode: CHP,
ACP, and SEM. As of XA25, five new power measurements: CCDF, IQ Waveform,
760 Short Range Comms & IoT Mode User's &Programmer's Reference