10 Hardware-Accelerated Fast Power Measurement (Remote Command Only)
10.6 Fetch Fast Power Measurement (Remote Command Only)
10.6 Fetch Fast Power Measurement (Remote Command Only)
Used to retrieve the results of an acquisition initiated by :INIT. The returned results
are in ASCII string format. The string begins and ends with quotation marks.
Remote
Command
:CALCulate:FPOWer:POWer[1,2,…,999]:FETCh?
Example
:CALC:FPOW:POW1:FETC?
Notes Option FP2 is required
Returns m comma-separated ASCII values, where m corresponds to the number of bandwidths defined
1. Declared function return in the 1st specified channel
2. Declared function return in the 2nd specified channel
…
m. Declared function return in the last specified channel
The INIT and FETC? command sequence has the same effect as a single CALC:FPOW:POW[n]?
query. Units of the returned values depend on "Channel Measurement Function Array" on page 2520 for
each channel
2526 Short Range Comms & IoT Mode User's &Programmer's Reference