6 Input/Output
6.1 RF Source
:SOUR:SYNC:REM:ADDR:DEL
Sync Runtime Settings (Remote Command Only)
Lets you Sync runtime settings to the Secondary modules without restarting Sync.
Remote
Command
:SOURce:SYNC:RTSetting:STATe ON | OFF | 1 | 0
:SOURce:SYNC:RTSetting:STATe?
Example
:SOUR:SYNC:RTS:STAT ON
:SOUR:SYNC:RTS:STAT?
Notes When OFF, Sync is interrupted when changing frequency or power settings on the Primary module.
After applying the new settings to the Secondary modules, Sync will restart
When ON, setting changes on the Primary module are applied to the Secondary modules immediately
without interrupting Sync status. This is the default behavior. The supported settings are Amplitude and
Frequency
Preset
ON
Range
ON|OFF
6.1.13.4 Sync Start
Lets you start synchronizing Primary and Secondary modules to play Arb
synchronously.
When the Sync connection is built successfully, Primary and Secondary modules are
in the Sync State.
Sync Start and Sync Config menu are grayed-out when Primary and Secondary
modules are in Sync State.
Remote
Command
:SOURce:SYNC:STARt
Example
:SOUR:SYNC:STAR
Notes If you change the source settings during Sync State, an error message appears in the status bar:
"Settings conflict; Sync connection is already established” and the change will not be applied until Sync
Stop
6.1.13.5 Sync Stop
Stops the synchronization.
When Sync Stops, Sync Config menu and Sync Start will be available.
Remote Command
:SOURce:SYNC:STOP
Example
:SOUR:SYNC:STOP