8 Trigger
8.1 Trigger
8.1.1.7 External 3
When External 3 is selected, a new sweep/measurement starts when the external
trigger condition is met using the TRIGGER 3 IN input connector on the rear panel.
This control only appears in certain instrument and option combinations, as follows.
For N9042B, selects the Precision External Trigger, but available only when IF
Path is 255 MHz or wider. The resolution will be within one sample count of the
4.8GHz ADC sampling rate for 255 ~ 2 GHz IF Paths, and within one sample
count of the 10.2GHz sampling rate for the 4 GHz IF Path
For all other instruments, available only if Option H1G is installed. It is only
available when the 1 GHz path is chosen, either directly or indirectly; in all other
paths it is visible but grayed-out. Direct and indirect selection of the 1 GHz path
occurs as follows:
Direct: Measurements that directly support the 1 GHz path have a 1 GHz
selection in the IF Path menu in Meas Setup
Indirect: Certain measurements, such as Power Statistics CCDF (PST), always
choose the widest available path, and so will choose the 1 GHz path if it is
available, even if there is no IF Path menu for the measurement. External 3
will be visible when this results in the 1 GHz path being selected, even if
there is no control or readout indicating that the 1 GHz path has been
selected
For a full list of Modes and measurements that support External 3, see "External 3
Support" on page 2318 in the section "Select Trig Source" on page 2315.
When External 3 is set, and then becomes disabled because you switched away
from the 1 GHz path, the Trigger Source selection reverts to the default ("Free Run"
on page 2328).
When External 3 Trigger is selected, the Trigger tab displays the following Trigger
Source dependent controls:
"Prot Frame Aligned" on page 2340
"Trigger Delay" on page 2343
"Trigger Slope" on page 2347
Additional controls are also present that are not dependent on the selected Trigger
Source.
Example
:TRIG:SPEC:SOUR EXT3
Sets External 3 as the trigger source for the Complex Spectrum measurement
Annunciation External 3 (in the Meas Bar)
Short Range Comms & IoT Mode User's &Programmer's Reference 2332

Table of Contents

Other manuals for Keysight x-series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight x-series and is the answer not in the manual?

Keysight x-series Specifications

General IconGeneral
Analysis BandwidthUp to 1 GHz (depending on model)
Real-Time BandwidthUp to 1 GHz (depending on model)
Form FactorBenchtop
ConnectivityLAN, USB, GPIB
Resolution Bandwidth1 Hz to 10 MHz (depending on model)

Related product manuals