3 Short-Range Comms & IoT Mode
3.7 ACP Measurement
knob, and it behaves as it normally would in manual mode
–
The Auto/Man state of (Mech) Atten is saved
–
The Auto/Man toggle on the (Mech) Atten control disappears, and the auto rules
are disabled
–
The Electronic Attenuator is set to 10dB less than the previous value of the
Mechanical Attenuator, within the limitation that it must stay within the range of
0 to 24dB of attenuation
Examples in the Dual-Attenuator configuration:
–
Mech Atten at 20dB. Elec Atten enabled, Mech Atten set to 10dB, and Elec
Atten set to 10dB. New total attenuation equals the value before Elec Atten
enabled
–
Mech Atten at 0dB. Elec Atten enabled, Mech Atten set to 10dB, and Elec Atten
set to 0dB. New total attenuation does not equal the value before Elec Atten
enabled
–
Mech Atten at 40dB. Elec Atten enabled, Mech Atten set to 10dB, and Elec
Atten set to 24dB. New total attenuation does not equal the value before Elec
Atten enabled
When the Electronic Attenuation is disabled from an enabled state:
–
The Elec Atten control is grayed out
–
The Auto/Man state of (Mech) Atten is restored
–
If now in Auto, (Mech) Atten recouples
–
If now in Man, (Mech) Atten is set to the value of total attenuation that existed
before the Elec Atten was disabled. The resulting value is rounded up to the
smallest value possible given the (Mech) Atten Step setting - (That is, 57dB
changes to 58dB when (Mech) Atten Step is 2dB)
Using the Electronic Attenuator: Pros and Cons
The electronic attenuator offers finer steps than the mechanical attenuator, has no
acoustical noise, is faster, and is less subject to wear.
The “finer steps” advantage of the electronic attenuator is beneficial in optimizing
the alignment of the instrument dynamic range to the signal power in the front
panel as well as remote use. Thus, you can achieve improved relative signal
measurement accuracy. Compared to a mechanical attenuator with 2dB steps, the
1dB resolution of the electronic attenuator only gives better resolution when the
odd-decibel steps are used. Those odd-decibel steps are less accurately calibrated
Short Range Comms & IoT Mode User's &Programmer's Reference 801