UDLD Commands
OmniSwitch 6250 CLI Reference Guide November 2009 page 27-9
udld echo-wait-timer
Configures the echo based detection timer on a specific port, a range of ports, or all the ports. This is
known as link detection period.
udld port [slot/port[-port2]] echo-wait-timer seconds
no udld port [slot/port[-port2]] echo-wait-timer
Syntax Definitions
slot/port The slot number for the module and the physical port number on that
module (e.g., 3/1 specifies port 1 on slot 3).
port2 The last port number in a range of ports that you want to configure on
the same slot (e.g, 3/1-4 specifies ports 1-4 on slot 3).
seconds The echo based detection period, in seconds (4-15).
Defaults
Platforms Supported
OmniSwitch 6250-Metro Models
Usage Guidelines
Use the no form of this command to reset the echo based detection timer to the default value. Note that
it is not necessary to specify the echo based timer to reset it.
The UDLD protocol must be enabled before using this command.
An echo message is expected in reply from the neighbor within this time duration, otherwise, the port
is considered as faulty.
Examples
-> udld echo-wait-timer 9
-> udld port 1/5 echo-wait-timer 12
-> udld port 1/7-16 echo-wait-timer 12
-> no udld echo-wait-timer
-> no udld port 1/3 echo-wait-timer
Release History
Release 6.6.1; command was introduced.
parameter default
seconds 8