LINK OAM Commands
OmniSwitch 6250 CLI Reference Guide November 2009 page 26-21
efm-oam errored-frame-seconds-summary
Configures the threshold, window and notify-status for errored-frame-seconds-summary on a port. The
Errored Seconds are the time in seconds in which at least one frame error has occurred.
efm-oam port slot/port[-port2] errored-frame-seconds-summary [threshold threshold_seconds]
[window window_seconds] [notify {enable | disable}]
Syntax Definitions
slot/port The slot number for the module and the physical port number on that
module (e.g. 3/1 specifies port 1 on slot 3).
-port2 The last port number in a range of ports that you want to configure on
the same slot (e.g 3/1-4 specifies ports 1,2,3, and 4 on slot 3).
threshold_symbols Specifies the frame error threshold number.
window_seconds Specifies the window of time in which the frame errors will be
measured.
enable Enables notification of the Errored Frame Seconds Summary event.
disable Disables notification of the Errored Frame Seconds Summary event.
Defaults
Platforms Supported
OmniSwitch 6250.
Usage Guidelines
• The various options, threshold, window and notify can be issued in any order. However, at least one
option has to be entered.
• To enter many ports in a single command, use a hyphen to specify a range of ports (e.g. 3/1-16).
Examples
-> efm-oam port 1/1 errored-frame-seconds-summary threshold 1 window 700 notify
enable
-> efm-oam port 1/1 errored-frame-seconds-summary notify disable
-> efm-oam port 2/1-4 errored-frame-seconds-summary threshold 1 window 700 notify
enable
-> efm-oam port 2/1-2 errored-frame-seconds-summary notify disable
parameter default
threshold_symbols 1 errored frame second
window_seconds 60 seconds. (600 dsec).
enable | disable enable