Configuration File Manager Commands
page 9-4 OmniSwitch 6250 CLI Reference Guide November 2009
configuration error-file limit
Specifies the maximum number of configuration error files allowed in the switch’s /flash directory. Error
files are normally generated when a configuration file is applied to the switch. Error files are identified by
their .err extension.When the maximum number of .err files is exceeded, any new error file will over-
write the .err file with the oldest timestamp.
configuration error-file limit number
Syntax Definitions
number Indicate the number of error files allowed in the /flash directory. The
valid range is from 1 to 25 files.
Defaults
Platforms Supported
OmniSwitch 6250
Usage Guidelines
When the error file limit is set to 1 (the default value), the next error file generated by the switch will
replace the existing one.
When the error file limit is set to a value greater than 1, when a new error file that exceeds the
maximum limit is created, the switch will automatically remove the error file with the smallest times-
tamp.
The error files generated by the switch have the .err extension.
If you want to save an error file, you may change the file name so that it does not have the .err
extension, or you can move it from the /flash directory.
Examples
-> configuration error-file limit 2
-> configuration error-file limit 1
Release History
Release 6.6.1; command was introduced.
parameter default
number 1