LINK OAM Commands
OmniSwitch 6250 CLI Reference Guide November 2009 page 26-19
efm-oam errored-frame
Configures an error frame threshold or window on a LINK OAM port and set notification status for
errored frame events. When the number of frame errors exceeds a threshold within a given window
defined by a period of time (for example, 10 frames in 1 second had errors), an Errored Frame Event is
generated.
efm-oam port slot/port[-port2] errored-frame [threshold threshold_symbols] [window
window_seconds] [notify {enable | disable}]
Syntax Definitions
slot/port The slot number for the module and the physical port number on that
module (e.g. 3/1 specifies port 1 on slot 3).
-port2 The last port number in a range of ports that you want to configure on
the same slot (e.g 3/1-4 specifies ports 1,2,3, and 4 on slot 3).
threshold_symbols Specifies the frame error threshold number.
window_seconds Specifies the window of time, in which the frame errors will be
measured. The duration should be in units of 100ms.
enable Enables notification of the Errored Frame event.
disable Disables notification of the Errored Frame event.
Defaults
Platforms Supported
OmniSwitch 6250.
Usage Guidelines
• The various options, threshold, window and notify can be issued in any order. However, at least one
option has to be entered.
• To enter many ports in a single command, use a hyphen to specify a range of ports (e.g. 3/1-16).
Examples
-> efm-oam port 1/1 errored-frame threshold 10 window 32 notify enable
-> efm-oam port 1/1 errored-frame notify disable
-> efm-oam port 2/1-4 errored-frame threshold 10 window 32 notify enable
-> efm-oam port 2/1-2 errored-frame notify disable
parameter default
threshold_symbols 1 frame error
window_seconds 1 second (10 dsec)
enable | disable enable