Chassis Management and Monitoring Commands
page 2-56 OmniSwitch 6250 CLI Reference Guide November 2009
show stack status
Displays the current redundant stacking cable status and token availability for a stacked configuration.
show stack status
Syntax Definitions
N/A
Defaults
N/A
Platforms Supported
OmniSwitch 6250
Usage Guidelines
N/A
Examples
-> show stack status
Redundant cable status : present
Release History
Release 6.6.1; command was introduced.
Related Commands
MIB Objects
alaStackMgrStackStatus
alaStackMgrTokensUsed
alaStackMgrTokensAvailable
output definitions
Redundant cable status Indicates whether a redundant stacking cable is currently installed.
Options include present and not present. To provide added resiliency
and redundancy, it is strongly recommended that a redundant stacking
cable is connected from the top switch in the stack to the bottom switch
in the stack at all times. For more information on stack redundancy,
refer to the “Managing OmniSwitch 6250 Series Stacks” chapter in the
OmniSwitch 6250 Series Hardware Users Guide.
show stack topology Displays the current operating topology of switches within a stack.