Ethernet Port Commands
page 20-28 OmniSwitch 6250 CLI Reference Guide November 2009
interfaces hybrid crossover
Configures port crossover settings on a single port, a range of ports, or an entire Network Interface (NI).
interfaces slot[/port[-port2]] hybrid copper crossover {auto | mdix | mdi}
Syntax Definitions
slot Slot number you want to configure.
port Port number of the interface you want to configure.
port2 Last port number in a range of ports you want to configure.
copper Specifies that changes will be made to the copper RJ-45 port(s).
auto The interface will automatically detect crossover settings.
mdix Sets the crossover configuration to Media Dependent Interface with
Crossover (MDIX), which is the standard for hubs and switches.
mdi Sets the crossover configuration to Media Dependent Interface (MDI),
which is the standard for end stations.
Defaults
Platforms Supported
OmniSwitch 6250
Usage Guidelines
• You cannot configure crossover settings on fiber ports. These ports use the MDI standard.
• The MIB table and MIB object listed in the “MIB Objects” section below apply to the inactive config-
ured media only. See the “MIB Objects” section in the interfaces crossover section for the MIB table
and MIB object for the active configured media.
Examples
-> interfaces 1/25 hybrid copper crossover disable
-> interfaces 1/25-26 hybrid copper crossover mdix
-> interfaces hybrid copper crossover auto
Release History
Release 6.6.1; command was introduced.
parameter default
auto | mdix | mdi auto