efm-oam port remote-loopback start
Initiates the loopback control PDU towards the peer port to start or stop the loopback session on the speci-
fied port.
efm-oam port slot/port remote-loopback {start | stop}
Syntax Definitions
slot/port The slot number for the module and the physical port number on that
module (e.g. 3/1 specifies port 1 on slot 3).
start Specifies whether to start the loopback request.
stop Specifies whether to stop the loopback request.
Defaults
N/A
Platforms Supported
OmniSwitch 6250
Usage Guidelines
Before issuing this command, the LINK OAM port has to be in active mode and discovery of peer
ports has to be completed.
When loopback is started from a port towards a peer port which is configured to ignore the loopback
request, the loopback response timer will timeout and no error is displayed. In such case, verify the
loopback-state of two ports by using the command show efm-oam port remote detail.
The maximum number of simultaneous loopback sessions supported per network interface is 2. If a
third loopback is started through CLI, an error will be displayed at the CLI prompt.
Examples
-> efm-oam port 1/1 remote-loopback start
-> efm-oam port 1/1 remote-loopback stop
Release History
Release 6.6.1; command was introduced.