RIP Commands
page 33-20 OmniSwitch 6250 CLI Reference Guide November 2009
ip rip invalid-timer
Configures the RIP invalid timer value that defines the time interval during which a route will remain
active in Routing Information Base (RIB) before moving to the invalid state.
ip rip invalid-timer seconds
Syntax Definition
seconds The RIP invalid timer value, in seconds. The valid range is 3–360.
Defaults
Platforms Supported
OmniSwitch 6250
Usage Guidelines
The invalid time interval value must be three times the update interval value.
Examples
-> ip rip invalid-timer 270
Release History
Release 6.6.1; command was introduced.
Related Commands
MIB Objects
alaProtocolRip
alaRipInvalidTimer
parameter default
seconds 180
show ip rip Displays the RIP status and general configuration parameters (e.g.,
forced hold-down timer).