Switch Logging Commands
page 45-8 OmniSwitch 6250 CLI Reference Guide November 2009
swlog output flash file-size
Configures the size of the switch logging file.
swlog output flash file-size bytes
Syntax Definitions
bytes The size of the switch logging file. The minimum value is 32000 while
the maximum value is the total amount of free space in flash memory.
Defaults
Platforms Supported
OmniSwitch 6250
Usage Guidelines
• Use the ls command to determine the amount of available flash memory.
• This command can also be used on the secondary CMM.
Examples
-> swlog output flash file size 400000
Release History
Release 6.6.1; command was introduced.
Related Commands
MIB Objects
systemSwitchLoggingGroup
systemSwitchLoggingFileSize
parameter default
bytes 128000
swlog clear Clears the files that store switch logging data.
show log swlog Displays stored switch logging information from flash.
show swlog Displays switch logging information.