LINK OAM Commands
OmniSwitch 6250 CLI Reference Guide November 2009 page 26-31
show efm-oam port detail
Displays the LINK OAM configuration and other related parameters for a port.
show efm-oam port slot/port detail
Syntax Definitions
slot/port The slot number for the module and the physical port number on that
module (e.g. 3/1 specifies port 1 on slot 3).
Defaults
N/A.
Platforms Supported
OmniSwitch 6250.
Usage Guidelines
Use this command when you want to get LINK OAM configuration details for a specific port.
Examples
-> show efm-oam port 1/1 detail
OAM Status : enable,
Operational Status : activeSendLocal,
Mode : active,
Max OamPDU size : 1518,
Config Revision : 0,
Functions Supported : loopback,event notification,
Loopback Status : noLoopback,
Loopback Rx Status : ignore,
Max OamPDUs : 10,
KeepAlive Interval(seconds) : 10,
Hello Interval(seconds) : 5,
Dying Gasp Notify Status : enable,
Critical Event Notify Status : enable
Link Monitoring Window Threshold Notify
(errors) Status
------------------+------------+-------------+------------+---------------
errored-frame 10 dsec 10 frames enable
errored-frame-period 2000000 frames 10 frames enable
errored-frame-seconds-summary 600 dsec 1 framesec enable
Output fields are described here:
output definitions
OAM Status The state of LINK OAM on the port.
Operational Status The state of the port in discovering whether the peer has LINK OAM
capability or not.