Chassis Management and Monitoring Commands
OmniSwitch 6250 CLI Reference Guide November 2009 page 2-17
reload ni
Reloads (i.e., reboots) a specified Network Interface (NI) module.
reload ni [slot] number
Syntax Definitions
slot Optional command syntax.
number Slot (i.e., switch) number within a stack that represents the NI module
to be reloaded.
Defaults
N/A
Platforms Supported
OmniSwitch 6250
Usage Guidelines
The reload ni command reboots only the specified switch. However, if you use this command on a
switch that has a primary CMM role in a stack, it will no longer be primary. Instead, it will be second-
ary in a two-switch stack and idle in a stack consisting of three or more switches.
Examples
-> reload ni slot 2
-> reload ni 2
Release History
Release 6.6.1; command was introduced.
Related Commands
MIB Objects
chasEntPhysicalTable
chasEntPhysAdminStatus
reset
reload all Reloads all the NIs and CMMs in a chassis.
power ni Turns the power on or off for a specified Network Interface (NI)
module.
show ni Shows the hardware information and the current status for Network
Interface (NI) modules currently running in the chassis.