EasyManua.ls Logo

Alcatel-Lucent OmniSwitch 6250 - Checking the Fan Status; Additional Monitoring Commands

Alcatel-Lucent OmniSwitch 6250
2018 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chassis Management and Monitoring Commands
page 2-54 OmniSwitch 6250 CLI Reference Guide November 2009
Release History
Release 6.6.1; command was introduced.
State The current operational state of the corresponding switch. Options
include RUNNING (the switch is up and operating normally),
DUP-SLOT (the switch has a duplicate saved slot number and has auto-
matically entered pass-through mode), CLR-SLOT (the switch has
been manually “cleared” via the stack clear slot command and is now
in pass-through mode), OUT-SLOT (the current stacked configuration
already has eight switches and therefore cannot accommodate this
switch), OUT-TOK (there are not enough unused tokens remaining in
the current stacked configuration to accommodate this switch),
UNKNOWN (the switch’s current state is not known).
Saved Slot The designated saved slot number for the corresponding switch. The
saved slot number is the slot position the switch will assume following
a reboot. A value of zero (0) indicates that the switch has been
“cleared” and, as a result, is designated for pass-through mode. To
assign saved slot numbers, use the stack set slot command. To clear a
switch and designate it for pass-though mode, use the stack clear slot
command.
Link A State The current status of the stacking cable link at the switch’s stacking
port A. Options include UP, DOWN, or UNKNOWN.
Link A Remote NI The slot number of the switch to which stacking cable As remote end is
connected. In other words, if a switch in slot position 1 displays a
Link A Remote NI value of 3, this indicates that the stacking cable
plugged into slot 1 stacking port A is connected to the slot 3 switch. If
no stacking cable link exists, the value 0 displays.
Link A Remote Port The specific stacking port to which stacking cable As remote end is
connected. Options include StackA, StackB, and 0. If stacking cable As
remote end is connected to stacking port B on the other switch, the
value displays StackB. If no stacking cable link exists, the value 0
displays.
Link B State The current status of the stacking cable link at the switch’s stacking
port B. Options include UP, DOWN, or UNKNOWN.
Link B Remote NI The slot number of the switch to which stacking cable B’s remote end is
connected. In other words, if a switch in slot position 6 displays a
Link A Remote NI value of 7, this indicates that the stacking cable
plugged into slot 6 stacking port B is connected to the slot 7 switch.
Link B Remote Port The specific stacking port to which stacking cable B’s remote end is
connected. Options include StackA, StackB, and 0. If stacking cable
B’s remote end is connected to stacking port B on the other switch, the
value displays StackB. If no stacking cable link exists, the value 0
displays.
output definitions (continued)

Table of Contents

Other manuals for Alcatel-Lucent OmniSwitch 6250

Related product manuals