RIP Commands
page 33-24 OmniSwitch 6250 CLI Reference Guide November 2009
Release History
Release 6.6.1; command was introduced. 
Related Commands
MIB Objects
alaProtocolRip
alaRipProtoStatus
alaRipRouteNumber
alaRipHostRouteSupport
alaRipRedistRouteTag
alaRipUpdateInterval
alaRipInvalidTimer
alaRipGarbageTimer
alaRipHolddownTimer
alaRipForceHolddownTimer
Holddown interval The hold-down time interval, in seconds. Valid range is 0–120. Default 
is 0.
Forced Hold-Down Timer The forced hold-down time interval, in seconds. The valid range is 
0–120. Default is 0.
ip rip status Enables/disables RIP routing on the switch.
ip rip force-holddowntimer Configures the interval during which a RIP route remains in the 
forced hold-down state.
ip rip update-interval Configures the time interval during which RIP routing updates are 
sent out.
ip rip invalid-timer Configures the RIP invalid timer value that defines the time interval 
during which a route will remain active in Routing Information 
Base (RIB) before moving to the invalid state.
ip rip garbage-timer Configures the RIP garbage timer value that defines the time inter-
val, which must elapse before an expired route is removed from the 
RIB.
ip rip holddown-timer Configures the RIP hold-down timer value that defines the time 
interval during which a route remains in the hold down state.