Texas Instruments CC3235 SimpleLink Series - Master RECEIVE with Repeated START after Master TRANSMIT

Texas Instruments CC3235 SimpleLink Series
799 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Idle
Master oper
ates in
Master Transmit mode
STOP c
ondition is not
generated
Wri
te Slave
Address to
I2CMSA
Wri
te ---01011
to I2CMCS
Master oper
ates in
Master Receive mode
Repeated START
condition is generated
with changing data
direction
Idle
Functional Description
www.ti.com
218
SWRU543–January 2019
Submit Documentation Feedback
Copyright © 2019, Texas Instruments Incorporated
Inter-Integrated Circuit (I
2
C) Interface
Figure 7-11. Master RECEIVE with Repeated START after Master TRANSMIT