Idle
Master oper
ates in
Master Receive mode
STOP condition is not
generated
Wri
te Slave
Address to
I2CMSA
Wri
te ---0-011
to I2CMCS
Master oper
ates in
Master Transmit mode
Repeated START
condition is generated
with changing data
direction
Idle
www.ti.com
Functional Description