Chassis Management and Monitoring Commands
page 2-52 OmniSwitch 6250 CLI Reference Guide November 2009
Release History
Release 6.6.1; command was introduced.
Related Commands
MIB Objects
chasChassisTable
chasHardwareBoardTemp
chasHardwareCpuTemp
chasTempRange
chasTempThreshold
chasDangerTempThreshold
output definitions
Hardware Board
Temperature
The current chassis temperature as determined by the built-in tempera-
ture sensor. The temperature is displayed in degrees Centigrade (i.e.,
Celsius). This temperature is checked against the upper threshold value.
If the threshold is exceeded, a warning is sent to the user.
Hardware Cpu Temperature The current CPU temperature. The temperature is displayed in degrees
Centigrade (i.e., Celsius).
Temperature Upper
Threshold Range
The supported threshold range. When you specify a threshold for the
switch via the temp-threshold command, values may range from
31–94.
Temperature Upper
Threshold
The warning temperature threshold, in degrees Celsius. If the switch
reaches or exceeds this temperature, the primary switch or CMM’s
TEMP LED displays amber and a warning is sent to the user. Values
may range from 15–94. The default value is 60. For information on
changing the upper threshold value, refer to the temp-threshold com-
mand on page 2-23.
Temperature Range The current threshold status of the switch. Displays whether the switch
is UNDER THRESHOLD or OVER THRESHOLD. If the status is
OVER THRESHOLD, the primary CMM’s TEMP LED displays
amber and a warning is sent to the user.
Temperature Danger
Threshold
The factory-defined danger threshold. This field is not configurable. If
the chassis temperature rises above 80 degrees Centigrade, the switch
will power off all Network Interface (NI) modules until the temperature
conditions (e.g., chassis air flow obstruction or ambient room tempera-
ture) have been addressed and the switch is manually booted.
temp-threshold Sets the chassis warning temperature threshold.
show fan Shows the hardware information and current status for the chassis fans.