Ethernet Port Commands
OmniSwitch 6250 CLI Reference Guide November 2009 page 20-35
• If both autonegotiation and flow control are enabled on the same local interface, autonegotiation calcu-
lates operational flow control settings for that interface. Note that the operational settings, as shown in
the following table, override the configured settings as long as autonegotiation and flow control are
both enabled for the interface.
• If autonegotiation is disabled, the configured flow control setting is applied to the local interface.
Examples
-> interfaces 1 hybrid fiber tx-and-rx
-> interfaces 3/21-24 hybrid copper pause rx
-> interfaces 3/21-24 hybrid copper disable
Release History
Release 6.6.1; command was introduced.
Configured
Local Tx
Configured
Local Rx
Configured
Remote Tx
Configured
Remote Rx
Negotiated
Local Tx
Negotiated
Local Rx
No No No No No No
Ye s Ye s Yes Yes Ye s Yes
Yes No Yes No No No
No Ye s No Yes Yes Ye s
No No No Yes No No
Ye s Ye s No No No No
YesNoYesYesNoNo
No Ye s Ye s No No Yes
No No Yes No No No
Ye s Ye s No Ye s Yes Ye s
YesNoNoNoNoNo
No Ye s Ye s Yes Yes Ye s
No No Yes Yes No No
Ye s Ye s Yes No No No
YesNoNoYesYesNo
No Ye s No No No No