Ethernet OAM Commands
page 25-42 OmniSwitch 6250 CLI Reference Guide November 2009
Release History
Release 6.6.1; command was introduced.
output definitions
Admin State Indicates the administrative state (up or down) of the MEP.
Direction The direction of the MEP.
Slot/Port The slot/port number of the Bridge port to which the MEP is attached.
MAC Address The MAC address of the MEP.
Fault Notification Indicates the current state of the MEP Fault Notification
Generator State Machine, which can be FNG_RESET,
FNG_DEFECT, FNG_REPORT_DEFECT,
FNG_DEFECT_REPORTED, or FNG_DEFECT_CLEARING.
CCM Enabled Indicates whether the MEP generates CCMs (enabled) or not (dis-
abled).
CCM Linktrace Priority Indicates the priority value for CCMs and LTMs transmitted by the
MEP.
CCM Not Received Indicates if CCMs are not being received (true) or received (false)
from at least one of the configured remote MEPs.
CCM Error defect Indicates if a stream of erroneous CCMs is being received (true) or not
(false) from a MEP in this MA.
CCM Xcon defect Indicates if a stream of CCMs is being received (true) or not (false)
from a MEP that belongs to another MA.
MEP RDI Received Indicates that any other MEP in this MA is transmitting the RDI bit.
Options include true or false.
MEP Last CCM Fault The last-received CCM that triggered a MA fault.
MEP Xcon Last CCM Fault The last-received CCM that triggered a cross-connect fault.
MEP Error Mac Status Indicates a port status TLV. Options include true or false.
MEP Lbm NextSeqNumber The next Transaction Identifier or Sequence Number to be sent
in an LBM.
MEP Ltm NextSeqNumber The next Transaction Identifier or Sequence Number to be sent
in an LTM.
Fault Alarm Time The time interval during which one or more defects should be detected
before the fault alarm is issued
Fault Reset Time The time interval during which the fault alarm is re-enabled to process
faults
Lowest PrDefect Allowed The lowest priority defect that allowed to generate fault alarm.
Highest PrDefect Present The highest priority defect since the MEPs Fault Notification Generator
in reset state.