:SBUS<n> Commands 31
Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide 1007
:SBUS<n>:MANChester:IDLE:BITS
(see page 1610)
Command Syntax
:SBUS<n>:MANChester:IDLE:BITS <#bits>
<#bits> ::= minimum idle time, from 1.50 to 32.00 in 0.25 increments,
in NR3 format.
The :SBUS<n>:MANChester:IDLE:BITS command specifies the minimum idle time
or inter-frame gap time in terms of the number of bits.
Query Syntax
:SBUS<n>:MANChester:IDLE:BITS?
The :SBUS<n>:MANChester:IDLE:BITS? query returns the specified idle time in
terms of the number of bits.
Return Format
<#bits><NL>
See Also • ":SBUS<n>:MANChester:BASE" on page 1001
• ":SBUS<n>:MANChester:BITorder" on page 1003
• ":SBUS<n>:MANChester:LOGic" on page 1008
• ":SBUS<n>:MANChester:STARt" on page 1011