866 Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
31 :SBUS<n> Commands
:SBUS<n>:A429:FORMat
(see page 1610)
Command Syntax
:SBUS<n>:A429:FORMat <format>
<format> ::= {LDSDi | LDSSm | LDATa}
The :SBUS<n>:A429:FORMat command specifies the word decode format:
•LDSDi:
• Label - 8 bits.
• SDI - 2 bits.
• Data - 19 bits.
• SSM - 2 bits.
• LDSSm:
• Label - 8 bits.
• Data - 21 bits.
• SSM - 2 bits.
•LDATa:
• Label - 8 bits.
• Data - 23 bits.
Query Syntax
:SBUS<n>:A429:FORMat?
The :SBUS<n>:A429:FORMat? query returns the current ARINC 429 word decode
format setting.
Return Format
<format><NL>
<format> ::= {LDSD | LDSS | LDAT}
Errors • "-241, Hardware missing" on page 1551
See Also • "Introduction to :SBUS<n> Commands" on page 853
• ":SBUS<n>:MODE" on page 857
• ":SBUS<n>:A429:TRIGger:PATTern:DATA" on page 871
• ":SBUS<n>:A429:TRIGger:PATTern:SDI" on page 872
• ":SBUS<n>:A429:TRIGger:PATTern:SSM" on page 873
• ":SBUS<n>:A429:TRIGger:TYPE" on page 875
• ":SBUS<n>:A429:SIGNal" on page 867
• ":SBUS<n>:A429:SPEed" on page 869
• ":SBUS<n>:A429:BASE" on page 861
• ":SBUS<n>:A429:SOURce" on page 868

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies InfiniiVision 4000 X Series and is the answer not in the manual?

Keysight Technologies InfiniiVision 4000 X Series Specifications

General IconGeneral
BrandKeysight Technologies
ModelInfiniiVision 4000 X Series
CategoryTest Equipment
LanguageEnglish

Related product manuals