:POWer Commands 28
Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide 739
:POWer:HARMonics:LINE
(see page 1610)
Command Syntax
:POWer:HARMonics:LINE <frequency>
<frequency> ::= {F50 | F60 | F400 | AUTO}
The :POWer:HARMonics:LINE command specifies the line frequency setting for the
current harmonics analysis:
F50 — 50 Hz.
F60 — 60 Hz.
F400 — 400 Hz.
AUTO — Automatically determines the frequency of the Current waveform.
Query Syntax
:POWer:HARMonics:LINE?
The :POWer:HARMonics:LINE query returns the line frequency setting.
Return Format
<frequency><NL>
<frequency> ::= {F50 | F60 | F400 | AUTO}
See Also ":POWer:HARMonics:APPLy" on page 735
":POWer:HARMonics:DATA" on page 736
":POWer:HARMonics:DISPlay" on page 737
":POWer:HARMonics:FAILcount" on page 738
":POWer:HARMonics:POWerfactor" on page 740
":POWer:HARMonics:RUNCount" on page 743
":POWer:HARMonics:STANdard" on page 744
":POWer:HARMonics:STATus" on page 745
":POWer:HARMonics:THD" on page 746