:SBUS<n> Commands 31
Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide 1129
:SBUS<n>:USB:TRIGger:PCHeck
(see page 1610)
Command Syntax
:SBUS<n>:USB:TRIGger:PCHeck <string>
<string> ::= "nnnn" where n ::= {0 | 1 | X}
<string> ::= "0xn" where n ::= {0,..,9 | A,..,F|X|$}
The :SBUS<n>:USB:TRIGger:PCHeck command specifies the 4-bit PID check
portion of the trigger for the selected bus, in binary or hex.
See the :SBUS<n>:USB:TRIGger:PID commands for setting the PID.
Query Syntax
:SBUS<n>:USB:TRIGger:PCHeck?
The :SBUS<n>:USB:TRIGger:PCHeck? query returns the specified PID check
portion of the trigger.
Return Format
<string><NL>
<string> ::= "nnnn" where n ::= {0 | 1 | X}
See Also • ":SBUS<n>:USB:TRIGger:PID:DATA" on page 1130
• ":SBUS<n>:USB:TRIGger:PID:HANDshake" on page 1131
• ":SBUS<n>:USB:TRIGger:PID:SPECial" on page 1132
• ":SBUS<n>:USB:TRIGger:PID:TOKen" on page 1133