1334 Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
35 :TRIGger Commands
:TRIGger:GLITch:LEVel
(see page 1610)
Command Syntax
:TRIGger:GLITch:LEVel <level>[,<source>]
<level> ::= .75 x full-scale voltage from center screen in NR3 format
for internal triggers
<level> ::= ±(external range setting) in NR3 format
for external triggers (DSO models)
<level> ::= ±8 V for digital channels (MSO models)
<source> ::= {CHANnel<n> | EXTernal} for DSO models
<source> ::= {CHANnel<n> | DIGital<d>} for MSO models
<n> ::= 1 to (# analog channels) in NR1 format
<d> ::= 0 to (# digital channels - 1) in NR1 format
The :TRIGger:GLITch:LEVel command sets the trigger level voltage for the active
pulse width trigger.
Query Syntax
:TRIGger:GLITch:LEVel?
The :TRIGger:GLITch:LEVel? query returns the trigger level of the current pulse
width trigger mode. If all channels are off, the query returns "NONE."
Return Format
<level><NL>
See Also • "Introduction to :TRIGger Commands" on page 1295
• ":TRIGger:MODE" on page 1308
• ":TRIGger:GLITch:SOURce" on page 1338
• ":EXTernal:RANGe" on page 436