926 Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
31 :SBUS<n> Commands
:SBUS<n>:FLEXray:AUTosetup
(see page 1610)
Command Syntax
:SBUS<n>:FLEXray:AUTosetup
The :SBUS<n>:FLEXray:AUTosetup command automatically configures
oscilloscope settings to facilitate FlexRay triggering and serial decode.
Sets the selected source channel's impedance to 50 Ohms.
Sets the selected source channel's probe attenuation to 10:1.
Sets the trigger level (on the selected source channel) to -300 mV.
Turns on trigger Noise Reject.
Turns on Serial Decode.
Sets the trigger to the specified serial bus (n of SBUS<n>).
See Also "Introduction to :TRIGger Commands" on page 1295
":SBUS<n>:FLEXray:TRIGger" on page 934
":SBUS<n>:FLEXray:BAUDrate" on page 927
":TRIGger[:EDGE]:LEVel" on page 1326
":SBUS<n>:FLEXray:SOURce" on page 933