EasyManua.ls Logo

Keysight Technologies InfiniiVision 4000 X Series

Keysight Technologies InfiniiVision 4000 X Series
1762 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1238 Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
32 :SEARch Commands
:SEARch:SERial:UART:DATA
(see page 1610)
Command Syntax
:SEARch:SERial:UART:DATA <value>
<value> ::= 8-bit integer from 0-255 (0x00-0xff) in decimal,
<hexadecimal>, <binary>, or <quoted_string> format
<hexadecimal> ::= #Hnn where n ::= {0,..,9| A,..,F} for hexadecimal
<binary> ::= #Bnn...n where n ::= {0 | 1} for binary
<quoted_string> ::= any of the 128 valid 7-bit ASCII characters (or
standard abbreviations)
The :SEARch:SERial:UART:DATA command specifies a data value when searching
for UART/RS232 events.
The data value qualifier is specified using the :SEARch:SERial:UART:QUALifier
command.
Query Syntax
:SEARch:SERial:UART:DATA?
The :SEARch:SERial:UART:DATA? query returns the current data value setting.
Return Format
<value><NL>
<value> ::= 8-bit integer from 0-255 (0x00-0xff) in decimal format
See Also Chapter 32, “:SEARch Commands,” starting on page 1149
":SEARch:SERial:UART:MODE" on page 1239
":SEARch:SERial:UART:QUALifier" on page 1240