:SBUS<n> Commands 31
Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide 1123
:SBUS<n>:USB:TRIGger:DATA
(see page 1610)
Command Syntax
:SBUS<n>:USB:TRIGger:DATA <string>
<string> ::= "nnnn..." where n ::= {0|1|X}
<string> ::= "0xn..." where n ::= {0,..,9 | A,..,F | X | $}
The :SBUS<n>:USB:TRIGger:DATA command specifies the Data portion of the
trigger for the selected bus, in binary or hex.
See the :SBUS<n>:USB:TRIGger:DATA:LENGth command for setting the length of
the data value.
Query Syntax
:SBUS<n>:USB:TRIGger:DATA?
The :SBUS<n>:USB:TRIGger:DATA? query returns the specified Data portion of the
trigger.
Return Format
<string><NL>
<string> ::= "nnnn..." where n ::= {0|1|X}
See Also • ":SBUS<n>:USB:TRIGger:DATA:LENGth" on page 1124