:SBUS<n> Commands 31
Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide 937
:SBUS<n>:FLEXray:TRIGger:EVENt:BSS:ID
(see page 1610)
Command Syntax
:SBUS<n>:FLEXray:TRIGger:EVENt:BSS:ID <frame_id>
<frame_id> ::= {ALL | <frame #>}
<frame #> ::= integer from 1-2047
The :SBUS<N>:FLEXray:TRIGger:EVENt:BSS:ID command sets the frame ID used
by the Byte Start Sequence (BSS) event trigger. This setting is only valid if the
trigger mode is EVENt and the EVENt:TYPE is BSS.
Query Syntax
:SBUS<n>:FLEXray:TRIGger:EVENt:BSS:ID?
The :SBUS<n>:FLEXray:TRIGger:EVENt:BSS:ID? query returns the current frame ID
setting for the Byte Start Sequence (BSS) event trigger setup.
Return Format
<frame_id><NL>
<frame_id> ::= {ALL | <frame #>}
<frame #> ::= integer from 1-2047
See Also • "Introduction to :TRIGger Commands" on page 1295
• ":SBUS<n>:FLEXray:TRIGger:EVENt:TYPE" on page 938
• ":SBUS<n>:FLEXray:TRIGger:EVENt:AUToset" on page 936
• ":TRIGger:MODE" on page 1308
• ":SBUS<n>:FLEXray:TRIGger" on page 934

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies InfiniiVision 4000 X Series and is the answer not in the manual?

Keysight Technologies InfiniiVision 4000 X Series Specifications

General IconGeneral
BrandKeysight Technologies
ModelInfiniiVision 4000 X Series
CategoryTest Equipment
LanguageEnglish

Related product manuals