1020 Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
31 :SBUS<n> Commands
:SBUS<n>:NRZ:BASE
(see page 1610)
Command Syntax
:SBUS<n>:NRZ:BASE <base>
<base> ::= {HEX | DECimal | ASCii | BINary}
When the display format is WORD (see :SBUS<n>:NRZ:DISPlay), the
:SBUS<n>:NRZ:BASE command specifies the base for the NRZ bus decode and
Lister display.
•HEX — hexadecimal
• DECimal — unsigned decimal
• ASCii
When the display format is BIT, the only legal decode base value is BINary.
Query Syntax
:SBUS<n>:NRZ:BASE?
The :SBUS<n>:NRZ:BASE? query returns the decode number base setting.
Return Format
<base><NL>
<base> ::= {HEX | DEC | ASC | BIN}
See Also • ":SBUS<n>:NRZ:BITorder" on page 1022
• ":SBUS<n>:NRZ:IDLE:BITS" on page 1027
• ":SBUS<n>:NRZ:IDLE:STATe" on page 1028
• ":SBUS<n>:NRZ:LOGic" on page 1029